Main Products
- Polycarboxylic antiscalant and dispersant
- Eco-friendly antiscalant and dispersant
- Phosphonates Antiscalants, Corrosion Inhibitors and Chelating Agents
- Salts of Phosphonates
- Biocide and Algicide
- Built Scale & Corrosion Inhibitors and Pretreatment Filming Agents
- Corrosion Inhibitor
- Oxygen Scavenger
- Reverse Osmosis Chemicals
- TH-0100 Antiscalant and Dispersant for RO Membrane
- TH-150 Antiscalant and Dispersant for RO Membrane
- TH-200 Antiscalant and Dispersant for RO Membrane
- TH-191 Antiscalant and Dispersant for RO Membrane
- THASD-200 Antiscalant and Dispersant for RO Membrane
- TH-260 Acid Detergent for RO Membrane
- TH-261 Alkali Detergent for RO Membrane
- Other
Taico.Inc
Mobile: +1 302 690 1860
E-mail: mgt@taico-materials.com
ADD: 401 Cooper Landing Rd, C-18 Cherry Hill,
NJ 08008
TH-261 Alkali Detergent for RO Membrane
Properties:
The operation stability of RO system is determined by the pretreatment of original water quality. For any RO system, after 3-12 months, it should be polluted, thus the chemical cleaning is required. TH-261 is an alkali detergent designed for removal of oil, organic substances and bio-mucosa. It has the following properties
1. Suitable for all aromatic polyamide and acetate acid membranes.
2. Effectively remove oil, organic substances and bio-mucosa from membrane surface.
3. Temperature increased, the effect will be better.
4. Diluent pH 10.5±0.5
5. Liquid chemicals, mix well.
6. Can be used repeatedly.
TH-261 is an alkali liquid formula, it can remove oil, organic substances and bio-mucosa.
Dosage:
Dilute to 1-3%(1:45)
Specification:
Items | Index |
---|---|
Appearance | Colorless to pale yellow transparent liquid |
pH(1:45 water solution) | 10.0-11.0 |
Density (20℃)g/cm3 | 1.10±0.05 |
Storage temperature | Not lower than -5℃ |
Usage:
(1)Check water box, pipeline and filter, change the filter material if needed.
(2)Input q.v. RO effluence to water box.
(3)Input q.v. TH-261 to water box, mix the solution with water pump, measure pH.
(4)Clean the system repeatedly, measure pH 5-20 minutes. After pH rise to 4, input q.v. TH-261 or acid, till pH not rise, meaning cleaning is end.
(5)If pollution is serious, sometimes the first batch detergent should be evacuated and the next batch should be required.
(6)Pay attention to solution temperature, don’t exceed the required temperature .
Package:
200L plastic drum,IBC(1000L),customers’ requirement.
Safety and Protection:
Alkaline, Avoid contact with eye and skin, once contacted, flush with water.